Respirators and fit testing for silica dust
A respirator only protects you if it is the right type, certified, fitted to your face and worn properly every time. Here is what NSW rules and guidance expect.
Course and test are free. Certificate $49, paid only if you pass.
- Built to SafeWork NSW's 11 criteria
- Certificate + employer training record
- Verify by code or QR
- Secure payment by Stripe
Respirators are the last line of defence
Respiratory protective equipment (RPE) only protects the person wearing it, and only when it fits and is worn correctly. That's why dust controls come first. Under section 529B, processing is controlled when the business uses reasonably practicable controls, at least one listed dust control (isolation, an enclosed filtered cabin, wet suppression, on-tool extraction or local exhaust ventilation), and RPE for anyone still at risk.
RPE never counts when the business assesses whether processing is high risk. It can count towards keeping exposure under the limit only if all higher-order controls are in place and the RPE is worn correctly.
The standards
Section 529B(3) says RPE must comply with AS/NZS 1716:2012 and be selected, used and maintained under AS/NZS 1715:2009.
Filters and protection factors
Silica dust needs a particulate filter: P1, P2 or P3. Each type of respirator gives a minimum protection factor. The silica code of practice gives examples:
| Protection factor needed | Suitable RPE (examples) |
|---|---|
| Up to 10 | Half facepiece with a P1, P2 or P3 filter |
| Up to 50 | Full facepiece with a P2 filter, or a powered air-purifying respirator (PAPR) with a P2 filter and any head covering or full facepiece |
| Up to 100 | Full facepiece with a P3 filter, or a full-face air-hose mask (natural breathing type) |
For higher protection factors, a competent person selects RPE under AS/NZS 1715.
Safe Work Australia's silica page says RPE for silica is generally a minimum of a P2 efficiency half-face respirator. The right choice still depends on the business's assessment of the task and dust levels, and your silica risk control plan or SWMS should name it.
Checking compliance
- Buy from a reputable supplier and confirm the product is certified to AS/NZS 1716:2012.
- Compliant RPE usually shows the standard number on the respirator or its packaging.
- For filters rated to an overseas standard, ask the manufacturer or a competent person.
- Check the filter class matches what the plan requires.
Fit testing
Fit testing is required for tight-fitting half and full facepieces:
- before first use
- for each new make, model, style or size
- when facial features change
- at least once a year.
Qualitative testing (taste or smell) is for half facepieces only. Quantitative testing works for half and full facepieces. Record the test type, the respirator's make, model, style and size, the date and the result.
Fit checking
Do a fit check (seal check) every time you put on a tight-fitting respirator, using a positive or negative pressure check, just before you enter an area where RPE is needed. A fit check doesn't replace a fit test.
Facial hair
There must be no facial hair where the mask seals, during fit testing and use. The silica code says workers who aren't clean shaven must not be given tight-fitting RPE. Loose-fitting PAPR hoods or helmets don't need a fit test and are a practical option.
Training and program checks
The silica code says RPE training should be given at the start of employment and at least once a year after that, and the RPE program audited at least yearly.
Related reading: Module 7: choosing the right respirator · Module 9: fit testing and facial hair · what counts as high-risk processing · silica training in NSW
Frequently asked questions
Is a P2 mask always enough for silica?
Not always. Safe Work Australia says a P2 half-face respirator is generally the minimum, but the protection factor needed depends on the dust level. The business's assessment decides.
How often do I need a fit test?
Before first use, for each new make, model, style or size, when your face changes, and at least once a year.
Can I wear a tight-fitting mask with stubble?
No. There must be no facial hair where the mask seals. Ask about a loose-fitting PAPR hood or helmet.
What's the difference between a fit test and a fit check?
A fit test checks a specific respirator model and size on your face, at least yearly. A fit check is the quick seal check you do every time you put it on.
Do respirators make dusty work low risk?
No. Respirators are ignored in the high-risk assessment, and they are the last line of defence after dust controls.
Sources
Last reviewed 21 November 2026. Rules can change, so check the sources for the latest.
Related
Get your silica training done today
Free course and test, built to SafeWork NSW's 11 criteria. Pay $49 only if you pass, and get your certificate and employer training record straight away.