What is banned
Since 1 July 2024, the WHS Regulation (section 529D) has banned work with engineered stone in NSW: making, supplying, processing and installing engineered stone benchtops, panels and slabs. Since 1 January 2025, importing engineered stone has also been banned under the Customs (Prohibited Imports) Regulations 1956.
Engineered stone can contain up to 97% crystalline silica (Safe Work Australia). SafeWork NSW lists manufactured stone at 93% or more.
What engineered stone is
Under section 529A, engineered stone is an artificial product that is a crystalline silica substance, made by combining natural stone materials with other chemical constituents (such as water, resins or pigments), and that becomes hardened.
These are not engineered stone under the law:
- concrete and cement products
- bricks, pavers and similar blocks
- ceramic wall and floor tiles
- grout, mortar and render
- plasterboard and roof tiles
- porcelain products and sintered stone, unless they contain resin.
Natural stone and finished items such as sinks and sculptures are not banned either. But most of these products still contain crystalline silica, so the processing rules apply to them.
Legacy engineered stone
Legacy stone means engineered stone installed before the ban, plus stock that was never installed. Processing it is only allowed for:
- research and sampling
- removal of installed stone
- repair or minor modification of installed stone
- disposal.
Uninstalled or removed stone may only be processed for disposal. All of this work must be controlled (sections 529E and 529F).
The reinstallation exemption
SafeWork NSW exemption No. 24-035, in place from 9 May 2025, lets the same benchtop go back in the same place, for example after cabinetry work. Only minor modification or repair is allowed, the work must be controlled and notified, and it doesn't cover installing replacement stone.
Notify SafeWork NSW first
Before processing legacy engineered stone, the business must give SafeWork NSW written notice using the online form (section 529G). The notice states the type of work, the processing, the equipment, and how often and how long the work will be done.
- If stone was processed without knowing it was engineered stone, notify as soon as practicable.
- Notify again within 30 days of a change (section 529H).
- Notify again every 12 months while the work continues (section 529I). One notice covers 12 months, not each job.
- Keep copies for 5 years (section 529J).
Is my benchtop dangerous?
No, not while it is left alone. SafeWork NSW says installed engineered stone poses no health risk while undisturbed, and there is no need to remove it. If it needs removing, repairing or modifying, use a qualified tradesperson.
Enforcement
On 20 November 2026, SafeWork NSW announced that a stone business had been fined $105,000 over workers' risk of exposure to respirable crystalline silica from cutting manufactured stone in 2021 and 2022.
Related reading: silica training for stonemasons · what counts as high-risk processing · silica training in NSW · the free silica course
Frequently asked questions
Can I still install a new engineered stone benchtop?
No. Installing engineered stone benchtops, panels and slabs has been banned in NSW since 1 July 2024.
Are porcelain and sintered stone banned?
Not if they don't contain resin. They are still crystalline silica substances, so cutting them must be controlled.
Can I cut an old benchtop to fit a new sink?
Minor modification of installed legacy stone is allowed if the work is controlled and SafeWork NSW was notified in writing before it started.
Do I need to notify SafeWork NSW for every job?
No. One notice covers 12 months. Notify again within 30 days of a change and every 12 months while the work continues.
Should I rip out my existing benchtop?
No. SafeWork NSW says installed engineered stone poses no health risk while undisturbed.
Sources
Last reviewed 21 November 2026. Rules can change, so check the sources for the latest.
Related
Get your silica training done today
Free course and test, built to SafeWork NSW's 11 criteria. Pay $49 only if you pass, and get your certificate and employer training record straight away.